Oxygen Sensor, Checking
^ engine oil temperature, min. 80~C (176~F)^ idle adjustment OK
^ control unit oxygen regulating function OK
^ remote control US 4480/3 not connected
^ oxygen sensor connected
^ connect test equipment for measuring OXS duty cycle
- start engine and let idle for at least 2 min.
- clamp hose (1) of idle speed stabilizer valve together tightly
- remove hose (2) from connecting piece on intake manifold
- hold connecting piece on intake manifold closed and note reading on test equipment
^ duty cycle reading must drop
If NO:
- replace oxygen sensor