Checking
Hall sender unit, checkingRequirement
- Electrical check of Digifant system OK
Voltage supply, checking
remove harness connector from Hall sender (on distributor)
- switch multimeter US 1119 to 20 volt range
- connect multimeter to outer terminals of harness connector
- switch ON ignition
- 10 volts minimum
If less than 10 volts
- replace Digifant control unit
If zero volts
- locate and eliminate open circuit in wiring using wiring diagram