Ignition Reference Sensor
Ignition Reference Sensor:
1. With the ignition "OFF", disconnect the ignition reference sensor harness connector.
2. Connect a suitable volt/ohm meter between terminals 1 and 2 of the ignition reference sensor.
Measure the resistance between terminal 1 and 2.
^ The correct measurement should be less than 2 ohms.
3. Measure the resistance between terminal 1 and ground.
4. Measure the resistance between terminal 2 and ground.
^ The correct measurement should be infinite ohms.
5. If the correct measurements are not obtained the sensor is defective. Replace the reference sensor