Operation CHARM: Car repair manuals for everyone.

Air Flow Meter/Sensor

BASIC ADJUSTMENT
depth measurement from fuel distributor mounting surface-
to sensor plate lever (roller)
0.74 in. ± 0.004 in. (18.8 mm ± 0.1 mm)

SENSOR PLATE FREE PLAY
basic adjustment
(control plunger stop screw) 0.024 in. (0.06 mm)
free play at sensor plate (maximum) 0.118 in. (3.0 mm)
gap at control plunger 0.020 in. (0.5 mm)

SENSOR PLATE REST POSITION
distance from sensor plate at rest (side nearest fuel distributor)-
to top of narrowest diameter of air cone
minimum 0.075 in. (1.9 mm)
maximum 0.118 in. (3.0 mm)