Scan Tool Connecting and Initial Checks
Requirements
- Fuses 18 and 21 OK
- Ground connections OK (engine ground connection: at cylinder head cover on left and beneath lower section of the intake manifold).
DLC Location Passat:
VAG 1551 connection
- Connect Scan Tool VAG 1551 using adaptor cable VAG 1551/3 to connect scan tool to 16 Pin Data Link Connector (DLC).The following displays appear alternately:
VAG On Board Diagnostic HELP
1-Rapid data transfer
VAG On Board Diagnostic HELP
2-Blink code output
Note: If there is no display, check the voltage supply for scan tool. Refer to VAG 1551 /Voltage Supply Checking.
VAG 1551 Selectable Functions:
Selectable Function Table
- Depending on which function is required; either switch ON ignition or start engine and let idle.
Note: If engine does not start, crank engine 4 to 6 seconds and leave ignition switched ON.
- To obtain additional operating instructions press the HELP button.
- To step through the program sequence, press the -> button
- Press button 1 to select operating mode "Rapid data transfer", Display will appear as follows:
Rapid data transfer HELP
Enter address word XX
- Press 0 and 1 buttons to select address word 01 "Engine electronics".Display will appear as follows:
Rapid data transfer Q
01-Engine electronics
- Press Q button to enter input. The engine control module identification number is indicated via the display, for example: 021 906 258 B. Display will appear as follows:
O21906258 B ENGINE
Coding 1
Note: Only during idle speed do correct specifications regarding the engine control module number and related coding occur.
- Press -> button. If display appears as follows:
Rapid data transfer HELP
ECM does not answer\
- Print out a list of possible causes by pressing the VAG 1551 HELP button.
- After eliminating possible causes, reselect operating mode and address word, display appears as follows:
Rapid data transfer HELP
Select function XX
- Select function code from Selectable Function Table
- Press Q button to enter input and see the proper procedure article for your selection.
Note: If function 02 Check DTC memory' (DTC MEMORY) is to be selected.
- Switch on the printer using the print button, lamp in print button lights.
- When the printer is switched ON stored malfunctions are automatically printed out in sequence.