Ignition System: Service Precautions
Safety precautionsCAUTION:
Observe the following precautions to prevent personal injury as well as possible damage to sensitive electrical components.
- switch OFF the ignition before connecting or disconnecting components or test equipment
- connect and disconnect battery ONLY with ignition switched OFF otherwise the control unit could be damaged
- do not touch or remove ignition wires with engine running or while cranking
- if the engine must be cranked but not started (for compression testing etc.) disconnect harness connector from ignition coil power output stage and remove fuse 18
- do NOT connect a condenser of any kind to terminal 1 of the ignition coil
- when installing noise suppressors, ONLY use 1000 Ohms for high tension wires and 5000 Ohms for spark plug connectors
- do NOT replace distributor rotor (marked R1) with a different type