Operation CHARM: Car repair manuals for everyone.

Access Procedure (BOAMV)

Measuring Value Block - Reading

1. With system in program 02 for transmission electronics, read display

Rapid data transfer HELP
Select function XX


2. Press keys 0 and 8 (this selects function 08 for reading measuring value block)

^ Read display:

Rapid data transfer Q
08 Read measuring value block


3. Press Q key to enter input

^ Read display:

Rapid data transfer HELP
Input display group number XX


4. Press keys 0 and 1 (this selects group number 01 and displays values corresponding to group 01 in following chart)

5. Press Q key to enter input

^ Read display

VAG 1551 Measuring Value Block Display:






6. Press --> key

7. Repeat group number entry for remaining groups (02 through 05) and press print key after each new display appears to print a record of diagnosis.

Note: Press keys 0 and 8 again before entering the next group number

^ Specified values on following tables
^ If specified values appear on all channels press -> key; the problem has not been found using this test sequence.
^ If specified values are not observed, conduct return to basic setting, and follow instructions in chart for further testing.

Measuring Value Block - Overview

OBD Measured Block Value Selectable Function Overview:





1. Group Numbers and Channel Number Designations