Access Procedure (BOAMV)
Measuring Value Block - Reading1. With system in program 02 for transmission electronics, read display
Rapid data transfer HELP
Select function XX
2. Press keys 0 and 8 (this selects function 08 for reading measuring value block)
^ Read display:
Rapid data transfer Q
08 Read measuring value block
3. Press Q key to enter input
^ Read display:
Rapid data transfer HELP
Input display group number XX
4. Press keys 0 and 1 (this selects group number 01 and displays values corresponding to group 01 in following chart)
5. Press Q key to enter input
^ Read display
VAG 1551 Measuring Value Block Display:
6. Press --> key
7. Repeat group number entry for remaining groups (02 through 05) and press print key after each new display appears to print a record of diagnosis.
Note: Press keys 0 and 8 again before entering the next group number
^ Specified values on following tables
^ If specified values appear on all channels press -> key; the problem has not been found using this test sequence.
^ If specified values are not observed, conduct return to basic setting, and follow instructions in chart for further testing.
Measuring Value Block - Overview
OBD Measured Block Value Selectable Function Overview:
1. Group Numbers and Channel Number Designations