Access Procedure (IONV)
Individual Measuring Values - Reading1. With system in program 02 for transmission electronics.
^ Read display:
Rapid data transfer HELP
Select function XX
2. Press keys 0 and 9 (this selects function 09 for reading individual test values)
^ Display reads:
Rapid data transfer Q
09 Read individual measuring value
3. Press Q key to enter input
^ Display reads:
Read individual measuring value
Feed in channel number XX
4. Press keys to input channel number of desired readout:
^ 00 test opening for solenoid valves (N 88, N 89, N 90) (not currently used)
^ 01 test opening for solenoid valves (N 91, N 92, N 94) (not currently used)
^ 02 voltage for transmission speed sender
^ 03 ATF temperature
^ 04 test opening for solenoid valve 6 (N 93)
^ 05 battery voltage
^ 06 not used
^ 07 voltage of throttle position sensor
5. Press Q key
^ Display reads:
Read individual measuring value
Channel 03 measuring value 2
6. Press keys 0 and 9 again before entering the next channel number.
^ specified values are on Tables A and B
^ if specified values are obtained, press --> button