SWITCHING TEMPERATURE SPECIFICATIONS
Standard Two Speed Thermo Switch Control:
Stage 1:
On 92-97°C (198-207°F)
Off 84-105°C (183-196°F)
Stage 2:
On 99-105°C (210-221°F)
Off 91-98°C (196-208°F)

Optional Third Speed Thermo Switch Control:
On 10-115°C (230-239°F)
Off 105-110°C (221-230°F)