Operation CHARM: Car repair manuals for everyone.

Access Procedure (BONV)

Measured Value Block - Reading

^ Measured Value Output Is In Numerical Values
^ For Output in Actual Measurements Values, See That Section

Note: When entering the measured value block, VAG 1551 displays numerical values of actual measurements depending on the date of manufacture of the control module

1. Connect Scan Tool VAG 1551, enter address code "02", Transmission Electronics, and move forward in program until "Select function XX" appears as in the display.

^ Readout in display:

Rapid data transfer HELP
Select function XX


2. Press buttons 0 and 8. (The function "Read measured value block" is started with 08.)

^ Readout in display:

Rapid data transfer Q
08 Read measured value block


3. Confirm entry with Q button.

^ Readout in display:

Read measured value block Help
Enter display group number XX


4. Press buttons 0 and 0.

5. Confirm entry with Q button.

^ Readout in display:

Read measured value block
1 2 3 4 5 6 7 8 9 10


6. See Specifications Tables

Notes:

^ Explanation of the Individual readouts in the display fields, See Specification tables.
^ If the specifications in display field 2 are not achieved, restore the system to the basic setting.
^ If the printer is switched on, the actual readout in the display is printed out on the log report.
^ If the specifications are achieved in all display fields

7. Press --> button.

^ Readout in display:

Rapid data transfer HELP
Select function XX