Access Procedure (IONV)
Individual Measured Value - Reading^ Measured value output is in numerical values
Notes:
^ When entering the measured value block VAG 1551 indicates numerical values of actual measurements depending on the date of manufacture of the control module
^ If the readout of the measured value block O8 is given in actual measurements, the measured value block O9 ("Reading individual measured value") can be ignored.
1. Connect Scan Tool VAG 1551, enter address code "02", Transmission Electronics, and move forward in program until Select function XX" appears as in the display.
^ Readout in display:
Rapid data transfer HELP
Select function XX
2. Press buttons 0 and 9. (The function "Read individual measured value " is initiated with 09).
^ Readout in display:
Rapid data transfer Q
09 Read individual measured value
3. Confirm entry with the Q button.
^ Readout in display:
Read individual measuring value
Feed in channel number XX
4. Indicate channel number:
00 - Test input for Solenoid Valves -N88-,-N69-,-N90-.
01 - Test input for Solenoid Valves -N91-. -N92-, -N94-.
02 - Vehicle Speed Sensor (VSS) -G68-.
03 - ATF temperature.
04 - Test input for Solenoid Valve -N93-.
05 - Battery voltage.
06 - Not assigned.
07 - Throttle Position (TP) Sensor -G69-.
^ Readout in display:
Read individual measuring value
Channel 03 measuring value 2
Notes:
^ See Specification Tables.
^ If the printer is switched on, the actual readout in the display is printed out on the log report
^ If the specifications are achieved in all display fields:
5. Press --> button.
^ Readout in display:
Rapid data transfer HELP
Select function XX