Starter Motor: Service and Repair
Starter, Removing/Installing
Starter application chart:
- 1.8 ltr.-2.O ltr. Gas
- 2.8 ltr. Gas
- Turbo Diesel engine (Canada only)
Removing:
- Disconnect ground cable at battery.
- Support engine/gearbox assembly with 1O-222A and legs 1O-222A/1.
- Cut through both cable ties -arrows- securing wiring from Generator (GEN) and from ignition switch terminal 50.
- After installation resecure wiring with two cable ties.
- Disconnect white and black connectors -arrows- and pull off.
- Disconnect wire from generator (GEN) B+ (6 mm2) (53 in. lb2) and wire from battery positive (16 mm2) (142 in. lb2) from starter terminal 30 -arrow-.
- When installing, tighten nut to 13 Nm (115 in.lb).
- Tighten securing bolt -arrow- to 60 Nm (44 ft lb).
- Tighten securing bolt -arrow- to 60 Nm (44 ft lb).