Oxygen Sensor Relay: Testing and Inspection
Electrical Checks at relay socket terminals
- Terminal-2, Battery voltage from fuse S-18
- Terminal-6, Battery voltage from ECM Power supply relay
- Terminal-4, Ground signal from ECM Terminal-28
- Terminal-8, Power output to Heated Oxygen Sensor connector Terminal-1
- Use wiring diagram to repair as necessary.