Operation CHARM: Car repair manuals for everyone.

096 Transmission

MEASURED VALUE BLOCK - READING

- Connect Scan Tool VAG 1551 and enter address code "02", Transmission electronics, and advance until "Select function XX" readout appears as in display.

^ Indicated on display:

Rapid data transfer HELP
Select function XX


- Press buttons 0 and 8. (To select function 08 "Read measuring value block").

^ Indicated on display:

Rapid data transfer Q
08 Read measuring value block


- Press Q button to confirm input.

^ Indicated on display:

Read measuring value block
Enter display group number XX


- Enter desired display group.

Display group 01 entered as an example.

See List of Selectable Display Groups section below for complete list of all Display groups.

- Press Q button to confirm input.

^ Indicated on display:

Read measuring value block 1 -->
-->1 -->2 -->3 -->4






- There are always 4 display fields in the measured value block (displayed in actual measurements).

- Explanation of values in the individual display fields (normal scan data values) are found in Scan Data Value Tables.





List of Selectable Display Groups

- If the printer is switched ON, the current display is pointed out on the log.

- If the values in all the display fields are as specified:

- Press --> key

^ Indicated on display:

Rapid data transfer HELP
Select function XX