Operation CHARM: Car repair manuals for everyone.

Selector Lever / Cable Assembly

SELECTOR LEVER







Disassembling and Assembling

Note:
Selector lever must be removed to replace individual parts.

1 - Selector lever
- Assembling - Fig. 1

2 - Indicator lighting
- Mounting indicator lighting connector - Fig. 4

3 - Spring

4 - Push rod
- Grease in area of sliding surfaces

5 - Guide sleeve
- Fit after installing push rod

6 - Set screw
- Always replace
- To remove, first remove Shift lock Solenoid and indicator lighting -2-. Clamp set screw in vice and loosen by turning selector lever
- Install with thread-locking fluid AMV 185 101 A1

7 - Shift lock Solenoid -N110-
- Adjusting - Fig. 2
- Functional check - Fig. 3
- Can be checked by On Board Diagnostic (OBD) program

8 - Screw
- Tightening torque: 3 Nm (27 in lb)
- Qty. 2
- Install with thread-locking fluid AMV 185 101 A1

9 - Nut
- Tightening torque: 5 Nm (44 in lb)
- Always replace

10 - Washer

11 - Locking lever
- For ignition lock
- Adjust together with locking cable

12 - Spring
- Hook into hole of detent plate

13 - Retainer
- For locking cable
- Removing and installing locking cable
- Adjusting locking cable

14 - Spring
- For locking pin

15 - Detent plate
- Assemble selector lever before fitting in selector lever housing - Fig. 1

16 - Locking pin
- With bracket

17 - Socket-head screw
- Tightening torque: 6 Nm (53 in lb)

18 - Screw
- Tightening torque: 6 Nm (53 in lb)

19 - Washer

20 - Spring
- Insert in selector lever together with lever -21-

21 - Lever
- For locking in selector lever position "N" or "P"
- Adjusting - Fig. 2

22 - Bushing

23 - Nut
- Tightening torque. 10 Nm (7 ft lb)
- Always replace

24 - Combi-bolt
- Grease shank








Fig. 1 Assembling selector lever before installing

Adjust Shift lock Solenoid -N110- (Fig. 2) and carry out functional check (Fig. 3) before installing selector lever in selector lever housing.

- Install set screw and Shift lock Solenoid -N110- mounting screws with thread-locking fluid AMV 185 101 A1.







Fig. 2 Adjusting Shift lock Solenoid -N110-
- Adjust solenoid by sliding in elongated holes until correct clearance -a- exists between push rod and lever - Fig. 3.






Fig. 3 Adjusting clearance between push rod and lever
Dimension -a = 0.3 mm (0.019 in.)

Functional check
- Shift selector lever into position "P" and supply Shift lock Solenoid -N110- with 12 Volts
- It must not be possible to shift selector lever into , driving gear.
- Interrupt solenoid operation.
- It must now be possible to shift into driving gears.
- Push rod must not catch on lever.
- Shift selector lever into "N" and check as in "P".
- After adjusting clearance, install assembled selector lever.






Fig. 4 Mounting indicator lighting connector
(Shift lock Solenoid with single wiring harness)
- Push bracket with lug (arrow) on until lug engages.
- Seat connector cable into bracket and slide connector onto bracket.