Battery - Low State of Charge
Group: 27Number: 97-03
Date: Sept. 17, 1997
Subject:
Generator B+ Terminal, Connection
Model(s):
Golf, GTI, Jetta 1994 -->VIN TM037600
Supersedes T.B. Group 27 Number 95-04 dated Apr. 18, 1995
Condition
Battery low state of charge can be caused by poor or intermittent electrical contact between wiring harness eyelet connector and Generator B+ terminal.
Service
- Obtain radio code.
- Disconnect battery ground (GND).
- Remove eyelet terminal from Generator B+ stud.
- Remove approximately 6 mm of the eyelet terminal insulation.
- Clean any residue or corrosion from eyelet terminal.
- Apply Stabilant 22A Part No. ZVW 186 001 to eyelet terminal.
- Reinstall eyelet terminal on Generator B+ stud.
^ Tightening torque: 13 Nm (10 ft. lb)
- Reconnect Battery (GND).
- Recode radio.
For warranty claims use:
Part Identifier: 2722
Labor operation: 2722213 20 TU