Opening Pressure
New Injector | 190 to 200 Bar (bar) |
Wear Limit | 170 Bar (bar) |
Leak Checking | 150 Bar (bar) without leaks for 10 seconds |
New Injector | 190 to 200 Bar (bar) |
Wear Limit | 170 Bar (bar) |
Leak Checking | 150 Bar (bar) without leaks for 10 seconds |