Operation CHARM: Car repair manuals for everyone.

Read Measuring Value Block, Function 08



6 display groups, with up to 4 display fields, can be displayed.

Requirement
- Connect VAG1551 scan tool, input address word 56 "Radio" and press -> button, until "Select function XX" appears on display.

Indicated on display

Rapid data transfer HELP
Select function XX


- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.

Indicated on display

Rapid data transfer Q
08 - Read Measuring Value Block


- Press -Q- button to confirm input.

Indicated on display

Read Measuring Value Block HELP
Input display group number XXX


- Input display group number from table below.
- Press -Q- button to confirm input.

Indicated on display

Read Measuring Value Block 1 ->
1 2 3 4


NOTES:
- Decoding the figures in the individual display fields table below.
- With the printer switched on the information on the display will be printed-out.
- If the specifications are attained in all display fields:

- Press -> button.

Table of Display group numbers





NOTE:
After ending function "Read Measuring Value Block" check DTC memory (function 02). Checking DTC Memory, Function 02