Read Measuring Value Block, Function 08
6 display groups, with up to 4 display fields, can be displayed.
Requirement
- Connect VAG1551 scan tool, input address word 56 "Radio" and press -> button, until "Select function XX" appears on display.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display
Rapid data transfer Q
08 - Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block HELP
Input display group number XXX
- Input display group number from table below.
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block 1 ->
1 2 3 4
NOTES:
- Decoding the figures in the individual display fields table below.
- With the printer switched on the information on the display will be printed-out.
- If the specifications are attained in all display fields:
- Press -> button.
Table of Display group numbers
NOTE:
After ending function "Read Measuring Value Block" check DTC memory (function 02). Checking DTC Memory, Function 02