Measuring Value Blocks (Function 08)
Read Measuring Value Block (Function 08)
6 display groups, with up to 4 display fields, can be displayed.
Requirement
- Connect VAG1551 scan tool, input address word 56 "Radio" and press -> button, until "Select function XX" appears on display.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select function 08 "Read Measuring Value Block".
Indicated on display
Rapid data transfer Q
08 - Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block HELP
Input display group number XXX
- Input display group number from table.
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block 1 ->
1 2 3 4
NOTE:
- Decoding figures in individual display fields, test table.
- With printer switched on, display information will be printed-out.
- If specifications are attained in all display fields:
- Press -> button.
Table of display group numbers
Display group Display field in display
001 1 = Open
2 = Power Supply voltage in V
3 = Illumination in %
4 = S-contact status (on or off)
(Radio does not turn off)
002 1 = Front speakers
2 = OK, short circuit or open circuit
3 = Rear speakers
4 = OK, short circuit or open circuit
003 1 = Passive or active
2 = Antenna
3 = OK, short circuit or open circuit
4 = Open
004 1 = Active amplifier output:
0 - OK
1 - Short circuit to ground
2 = Open
3 = Open
4 = Open
005 1 = CD-changer connection
(even if CD-changer code is not set)
2 = OK or not OK
3 = Open
4 = Open
006 1 = External Display
2 = not OK
3 = Open
4 = Open
NOTE: After ending function "Read Measuring Value Block" check DTC memory (function 02) With Manufacturer Scan Tool (Function 02)