Operation CHARM: Car repair manuals for everyone.

Programming and Relearning




MFI adaptation


NOTE:
- Only an adjustment range of 85% - 715% is possible.
- Adjustment values are input in 5% steps.


Prerequisites
- Speedometer and odometer displays OK
- DTC memory of Engine Control Module (ECM) and instrument cluster checked and "No DTC recognized" appears in display.

Indicated on display (select function):


Rapid data transfer HELP
Select function XX



- Press buttons -1- and -0- to select function 10, "Adaptation"

Indicated on display:


Rapid data transfer Q
10 - Adaptation



- Press -Q- button to confirm input.

Indicated on display:


Adaptation
Enter channel number XX



- Press buttons -0- and -3- to select channel 03.

Indicated on display:


Adaptation ->
Enter channel number 03



- Press -Q- button to confirm input.

Indicated on display:


Channel 3 Adaptation 100
<-13->



- Forward with -> button.

Indicated on display:


Channel 3 Adaptation 100
Input adaptation value XXXXX


NOTE: Adaptation is only possible with direct input.

- Enter applicable correction value using VAG 1551/1552 button pad. Fill first positions with "0".

Example:
Value required: 90%; button pad entry: 00090

Indicated on display:


Channel 3 Adaptation 100 Q
Enter Adaptation value 00090



- Press -Q- button to confirm input.

Indicated on display:


Channel 3 Adaptation 90 Q
<-13->



- Press -Q- button to confirm input.

Indicated on display:


Channel 3 Adaptation 90 Q
Store changed value?



- Press -Q- button to confirm input.

Indicated on display:


Channel 3 Adaptation 90 ->
Changed value is stored



- Press -> button to complete adaptation sequence.

Indicated on display (select function):


Rapid data transfer HELP
Select function XX



- End output (function 06).

NOTE: A wrong entry switches scan tool to "Function" mode.

Will be indicated on display:


Function is unknown or ->
cannot be carried out at the moment



- Press -> button.
- Select function 10 "Adaptation" and adaptation channel 03 again.
- Carry out corrections to consumption indicator as described above and be sure to press -Q- button to confirm all inputs.