Adjusting Temperature Flap Cable
Adjusting temperature flap cable- Install fresh air/heating control assembly in instrument panel
- Adjust temperature control knob to full cold.
- Connect temperature flap cable (blue sleeve) to temperature flap lever.
- Push lever in direction of arrow to stop.
- Hold lever in this position and install cable retaining clip.