ECM, Adapting to Throttle Valve Control Module

NOTE:
- Only Initiate "Basic Setting" Function O4 When The Throttle Valve Control Module -J338-, The Engine Control Module (ECM) -J220- Or The Engine Has Been Replaced.
- Initiating Basic Setting Matches The ECM To The Throttle Valve Control Module With The Ignition Switched On.
- If The Basic Setting Is Interrupted By The ECM, It Can Be, That The Throttle Valve Is Not At The Mechanical Idle Stop Due To Dirt Contamination Or An Incorrectly Adjusted Accelerator Cable. In This Case The Malfunction "Basic Setting Not Performed" Will Be Stored In DTC Memory. Thoroughly Clean The Soiled Area In Throttle Valve Control Module. The Next Time The Ignition Is Switched On, Basic Setting Will Be Automatically Performed Again.


Special Tools, Testers And Auxiliary Items
- VAG 1551/1552 Scan Tool With VAG 1551/3 Adapter Cable

Test Conditions
- If no malfunctions are stored in the Diagnostic Trouble Code Memory, then see Function 02: Checking DTC memory for the next procedure.

Test sequence
- Connect VAG 1551/1552 scan tool and select "Engine Electronics" address word 01. When doing this the ignition must be switched on but the engine not running.

Indicated On Display

Rapid data transfer HELP
Select function XX

- Press buttons -0- and -4- for the "Basic Setting" function 04 and press -Q- button to confirm input.

Indicated On Display

Basic Setting HELP
Input display group number XXX

- Press buttons -0-, .9- and -8- for display group 098 and press -Q- button to confirm input.

Indicated On Display (1-4 = Display Fields)

System in Basic Setting 96
1 2 3 4

NOTE:
After Confirming The Display Group 098 The Throttle Position Actuator Will Be Moved To The Min., Max. And Then Into The Start Position. The Control Module Stores The Appropriate Throttle Valve Angle In The Permanent Memory. The Throttle Valve Will Then Remain In The Start Position.





Display Group 098: Basic Setting

- Check the specifications (Display Fields 1-4):
- Wait at least 30 seconds before ending basic setting by pressing the -> button.
- Press buttons -0- and -6- to select "End Output" function 06 and press -Q- button to confirm input.