Code Control Module (Function 07)
Code Control Module (function 07)
Coding is only possible when using a new control module.
- Connect Scan Tool (ST).
- Initiate On Board Diagnostic (OBD). On Board Diagnosis (OBD) For Airbag, Initiating
- Switch printer on via Print -button (indicator lamp in button illuminates).
Airbag Malfunction Indicator Lamp (MIL) K75 illuminates continuously.
Indicated on display (for current control module versions, see replacement parts catalog):
1J0 909 608 AIRBAG VW 3 S V03 -->
Coding 00000 WSC00000
- Press --> -button.
Indicated on display:
Rapid data transfer HELP
Select function XX
Rapid data transfer HELP
Select function XX
- Press buttons - 0 - and - 7 - to select "Code Control Module" function 07.
Indicated on display:
Rapid data transfer Q
07 Code control module
- Press Q button to confirm input.
Indicated on display:
Code control module
Enter code numbers XXXXX (0-32000)
- Enter code number according to table:
- Press Q button to confirm input.
Display indicates control module identification number with appropriate letter index, code number and workshop code.
1J0 909 608 A AIRBAG VW 3 S V03
Coding 00065 WSC 12345
Coding has been completed if specified content is indicated.
If code number entered is not accepted by control module, a notification of a malfunction
appears in display and entered, not accepted code number, e.g. 00200 is displayed:
Indicated on display:
MALFUNCTION -->
Coding 00200 not accepted
In this case, control module was not programmed with data required for vehicle. Coding is not possible then. Airbag Malfunction Indicator Lamp (MIL) K75 does not go out and illuminates continuously. It must be determined whether control module appropriate to vehicle was installed (compare part number and letter index) or whether incorrect code number was entered.
End function:
- Press --> -button.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons - 0 - and - 6 - to end output.
- Press Q button to confirm input.
Indicated on display:
Rapid data transfer Q
06 End Output
Airbag Malfunction Indicator Lamp (MIL) K75 must go out after a max. 4 seconds.