With Manufacturer's Scan Tool
Malfunction Indicator Lamp (MIL), Functional Check
Special tools and equipment
- VAG1598/22 test box
- Multimeter (Fluke 83 or equivalent)
- VW1594 adapter set
- Wiring diagram
Test requirements
Fuse Block:
- Fuses 10 and 29 OK
- Battery (B+) voltage at least 11.5 V
Functional check
- Turn on ignition.
The Malfunction Indicator Lamp (MIL) must light up.
If the Malfunction Indicator Lamp (MIL) does not light up with the ignition turned on:
- Check wiring from Motronic Engine Control Module (ECM) -J220- to Malfunction Indicator Lamp (MIL) as follows:
Wiring from Motronic Engine Control Module (ECM) -J220- Check:
If the Malfunction Indicator Lamp (MIL) lights up with the ignition turned on, continue check as follows:
- Start engine and run at idle.
- The Malfunction Indicator Lamp (MIL) must go out after a few seconds.
If the Malfunction Indicator Lamp (MIL) does not go out:
- Check DTC memory. If necessary, repair any malfunctions and erase DTC memory.
Reading Diagnostic Trouble Codes
Clearing Diagnostic Trouble Codes
If no DTCs are stored:
- Display readiness code. Monitors, Trips, Drive Cycles and Readiness Codes
If DTC memory has been erased or the Motronic Engine Control Module (ECM) -J220- was disconnected from permanent battery (B+) voltage, generate the readiness code again. Monitors, Trips, Drive Cycles and Readiness Codes