Read Measuring Value Block (Function 08)
NOTE: 6 display groups display up to 4 measuring values each.- Connect VAG 1551 Scan Tool (ST), input address word 56 "Radio" and then press -> button, until "Select function XX" is shown in display.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select function 08," Read measuring value block."
Indicated on display:
Rapid data transfer Q
08 - Read measuring value block
- Press -Q- button to confirm input.
Indicated on display:
Read measuring value block Q
Enter display group number XX
- Enter desired display group number and press -Q- button to confirm input.
Indicated on display:
Read measuring value block X ->
1 2 3 4
NOTES:
- Interpreting measured values in individual display fields. See table below.
- With the printer switched on, the information on the display will he printed Out.
- Press -> button if measured value specifications are met in all display fields.
Table Of Selectable Display Group Numbers:
Display Designations
group
number
001 1 = Open
2 = Power supply voltage
3 = Illumination in %
4 = S-contact status (on or off)
002 1 = Front speakers
2 = OK, snort or open circuit
3 = Rear speakers
4 = OK, short or open circuit
003 1 = Passive or active
2 = Antenna
3 = OK, short or open circuit
4 = Open
004 1 = 0 (Power output to active amplifier OK)
1 = 1 (Power output to active amplifier short to ground)
2 = Open
3 = Open
4 = Open
005 1 = CD changer installed (even when not coded in radio)
2 = OK or not OK
3 = Open
4 = Open
006 1 = Ext. Displ.
2 = OK or not OK (if OK, check control module -radio- coding)
3 = Open
4 = Open
NOTE: After ending function 08 "Read Measuring Value Block" check DTC memory (function 02).