Solenoid Valves, Checking
Solenoid Valves, Checking
- Respective fuses must be OK.
- Battery voltage must be at least 11.5 volts.
- Selector lever must be in -P- position.
- Ground (GND) connections to transmission must be OK.
- Transmission must be OK mechanically.
Test sequence
- Disconnect 20-pin harness connector to Direct Shift Gearbox (DSG) Mechatronic -J743- on transmission.
Observe safety precautions.
- Check harness connector for contact corrosion and ingress of water.
If harness connector is not OK:
- Repair the malfunction.
- Erase DTC memory of Transmission Control Module (TCM).
- Generate readiness code.
If harness connector is OK:
- Replace Direct Shift Gearbox (DSG) Mechatronic -J743-.
NOTE: Solenoid Valve 1 -N88- through Solenoid Valve 5 -N92- are components of the Direct Shift Gearbox (DSG) Mechatronic -J743- and cannot be replaced individually.