Operation CHARM: Car repair manuals for everyone.

Diesel Fuel Injection Components and Functions, Checking





Diesel Fuel Injection Components and Functions, Checking

WARNING!
Make sure that no electronic components are destroyed during testing by observing the following:
- Switch the Fluke 83 multimeter to the appropriate units range before connecting measuring cables!
- Always observe checking requirements!



NOTE:
- Use the Fluke 83 multimeter and VAG1527B Voltage tester for electrical checking.
- Specifications are valid for an ambient temperature range from: 0 to +40°C (+32 to 104°F)
- If measured values deviate only slightly from the specifications, clean the sockets and plugs on the tester and measuring cables, then repeat check. Before replacing a component, check wiring and connections. In cases of specifications less than 10 Ohms repeat the resistance measurement on the component.
- To connect a tester to the Test Box, use jumper wires from the VW1594 adapter kit.
- The terminal numbers of the plugs and the socket numbers on the Test Box are identical.