Reading Measuring Value Blocks
Read Measuring Value Block (function 08)
Use this function to determine immobilizer system status.
- Connect VAG 1551 Scan Tool (ST), input address word 17, "Instrument cluster", and press -> button until "Select function XX" appears in display. Scan Tool Connecting and Initial Checks
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select function 08," Read measuring value block".
Indicated on display
Rapid data transfer Q
08 - Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block
Input display group number XX
- Press button -0- once and -2- twice to enter display group 22.
- Press -Q- button to confirm input.
- Indicated on display (example only)
Read Measuring Value Block ->
1 1 1 2
NOTE:
- Interpreting measured values in individual display fields.
- When printer is switched on, the actual display is printed out.
- Press -> button if measured value specifications are met in all display fields.