Operation CHARM: Car repair manuals for everyone.

Reading Measuring Value Blocks




Read Measuring Value Block (function 08)

Use this function to determine immobilizer system status.
- Connect VAG 1551 Scan Tool (ST), input address word 17, "Instrument cluster", and press -> button until "Select function XX" appears in display. Scan Tool Connecting and Initial Checks

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -8- to select function 08," Read measuring value block".

Indicated on display


Rapid data transfer Q
08 - Read Measuring Value Block



- Press -Q- button to confirm input.

Indicated on display


Read Measuring Value Block
Input display group number XX



- Press button -0- once and -2- twice to enter display group 22.
- Press -Q- button to confirm input.
- Indicated on display (example only)


Read Measuring Value Block ->
1 1 1 2



NOTE:
- Interpreting measured values in individual display fields.
- When printer is switched on, the actual display is printed out.
- Press -> button if measured value specifications are met in all display fields.