Reading Measured Value Block
Additional information:
Electrical Wiring Diagrams & Component Locations.
Testing Procedure:
- Connect VAG 1551 scan tool, insert "Transmission Electronics" address word 02 and advance through program sequence until "Select function XX" appears on display.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display
Rapid data transfer Q
08 - Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display
Read measuring value block
Input display group number XXX
- Input desired display group number. See selectable display groups, as described below.
- Press -Q- button to confirm input.
The measuring value block always contains 4 display fields (showing physical quantities if required). Specifications for individual values in display fields 1-4, see Read Measuring Value Block table.
Read measuring value block 1 ->
->1 ->2 ->3 ->4
Selectable Display Groups:
Display groups 001 to 005
Display groups 006 to 011
NOTES:
- If the printer is switched ON, the current display will be printed out.
- If the indicated values in all display fields match specifications:
Press ->button.
Indicated on display
Rapid data transfer HELP
Select function XX