Initiating on Board Diagnostic (Central Locking System)
Convenience System, Initiating On Board Diagnostic (OBD)
Test prerequisites:
- Voltage supply and fuses for the respective system OK.
- To initiate the On Board Diagnostic (OBD) the ignition must be switched on "Terminal 15 on".
NOTE:
- If the display remains blank, check VAG1551 voltage supply according to wiring diagram.
- Additional operating information can be printed out depending on the program by pressing the HELP key of VAG1551.
- The -> key is used for advancing the program sequence.
- The PRINT key is used for switching on the printer (warning lamp in key lights up).
- Connecting scan tool. Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks", under "Restraint Systems", Testing and Inspection
- Switch on ignition.
- Switch on printer with Print button (warning lamp in button lights up).
- Press key -1- for "Rapid data transfer" mode.
Indicated on display:
Rapid data transfer HELP
Enter address word XX
Address word for the central locking: 35
Indicated on display:
Rapid data transfer HELP
Enter address word XX
- Press keys -3- and -5-.
Indicated in display after entering the address word 35.
Rapid data transfer Q
35 central locking
- Confirm entry with the Q button.
and then the following appears in the display:
Indicated on display:
Rapid data transfer
Tester sends the address word 35
The control unit identification will be shown on the scan tool VAG 1551 display, e.g.:
1C0982258 XX cent Lock 0001 ->
Coding XXXXX WSC XXXXX
- Press -> key.
Indicated on display:
Rapid data transfer HELP
Select function XX