Disassembly and Assembly
1 - Heating and ventilation controls
- With fresh air blower switch -E9-
- With switch for fresh air blower and recirculated air -E184-
2 - Illumination filter
3 - Trim panel
4 - Fresh air control lever light -L16-
- 12V, 1.2W
- Replacing:
- Unclip trim panel -item 7- and rotary control -item 5-.
- Pull out bulb using a piece of fuel hose.
5 - Rotary control
- For blower speed
- To remove: Use pliers with suitable plastic or rubber protection on jaws
6 - Rotary control
- For air distribution
- To remove: Use pliers with suitable plastic or rubber protection on jaws
7 - Trim panel
8 - Rotary control
- For interior temperature control
- To remove: Use pliers with suitable plastic or rubber protection for jaws