Measurement
5 Speed Manual 02J
Measurement, Checking
- Mount holder and dial indicator. Install end measuring plate on input shaft in transmission housing.
- Rotate input shaft so that tapered roller bearing settles.
- Press input shaft in direction of arrow.
- Bearing play: min. 0.01 - max. 0.09 mm.
Note: If the bearing clearance cannot be measured, but input shaft is perceptible and the input shaft turns freely, the adjustment is acceptable.