Reading
Read Measuring Value Block (Function 08)
NOTE:
- During the function Read measuring value block, the Climatronic regulation is in operation.
- 8 display group numbers display up to 4 measuring values each.
- To safely read measuring values while driving, an assistant is required.
- Connect VAG 1551 Scan Tool (ST) and enter address word "08 AC/Heating electronics" and then press button, until "Select function XX" is shown in display. Initiating and Checking Control Module Versions
Indicated on display (function selection):
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select function 08 Read measuring value block.
Indicated on display:
Rapid data transfer Q
08 - Read measuring value block
- Press -Q- button to confirm entry.
Indicated on display:
Read measuring value block
Enter display group number XXX
- Using the 1551 button pad, enter the required display group number (following example shows display group 001).
Indicated on display:
Read measuring value block Q
Enter display group number 001
- Press -Q- button to confirm entry.
Indicated on display:
Read measuring value block 1->
1 2 3 4
NOTE:
- Interpreting measured values in individual display fields See tables. Test Tables
- With the printer is switched on, the information on the display will be printed out.
- After completing the Read measuring value block function, check DTC memory.
- If measured value specifications are met in all display fields:
- Press -> button.
Indicated on display (function selection):
Rapid data transfer HELP
Select function XX
NOTE: To easily change between display groups, proceed as follows: