Shift Mechanism, Disassembling And Assembling
Shift Mechanism, Disassembling And Assembling
Lubricate all mounts and sliding surfaces with Polyuric grease Part No. G 052 142 A2.
1. Selector lever handle
- Press sleeve -item 2- down, pull knob out onto stop and pull handle off upward.
^ Installing
2. Sleeve
^ Installation position: Angled section faces inward
3. Cover
^ With selector indicator
4. Light conductor
^ With wiring and light emitting diodes (LED) for selector lever illumination
^ Wire routing; see Fig. 1
CAUTION: Check with your parts department for latest part number information.
5. Guide
^ To remove, release 4 retaining lugs on inner side
6. Spring
^ For pull rod
7. Pull rod
^ Insert together with spring in selector lever
8. Selector lever
9. Detent plate
^ Insert together with spring clip -item 10- in selector lever
10. Spring clip
^ Insert both ends in selector lever
11. Nut
^ 10 Nm (7ft. lbs.)
12. Mounting bracket
^ Removing and installing
13. Fulcrum pin
^ Pry out with screwdriver
14. Pin
^ For lever -item15- on mounting bracket
15. Lever
^ For locking cable
16. Locking cable
^ For ignition key removal lock
^ Must not be kinked
17. Circlip
18. Securing spring
^ For locking cable
19. Selector lever lock solenoid -N110-
^ Removing and installing; see Fig. 1
^ Can be checked in electrical test and in measured value block
20. Rubber housing
^ Must only be separated from mounting bracket (item 12) if damaged and when disassembling selector lever
21. Cover
^ For mounting bracket
^ Removing and installing
22. Securing clip
^ For selector lever cable at selector lever
23. Locking plate
^ For selector lever cable at mounting bracket
^ Installation position
24. Selector lever cable
^ Do not bend or kink, lightly grease cable eye and ball socket before installing.
^ Rubber boot must not be damaged
25. Support bracket
^ For selector lever cable
26. Bolt
^ 23 Nm (17 ft. lbs.)
27. Ignition/starter switch
Fig. 1 Removing and installing selector lever lock solenoid -N110- and wiring for selector lever illumination
- Disconnect connector -1- (wiring console).
- Turn magnet -2- approx. 90° in direction of arrow.
- Check selector mechanism after replacing magnet.
- Route cable for selector lever illumination under guide -3- and secure in notch -4- (left/right).
- Clip connector -5- into retainer on guide.
- Reconnect connector-1- (wiring console).