Alternator: Service and Repair
Generator
Removal
Caution: When disconnecting battery, the procedure must be followed as described in the repair manual.
- Disconnect battery. Refer to Service and Repair
- Bring lock carrier into service position. Refer to Service and Repair
- Drain coolant. Refer to Coolant
- Remove hose for crankshaft housing ventilation, open crankshaft housing retainer -arrows- to do so.
- Drain engine oil.
- Disconnect coolant hose -arrows-.
- Loosen coolant hose -arrow-.
- Loosen coolant hose -arrow-.
- Loosen coolant hose -arrow-.
- Remove water pipe toward coolant expansion tank.
- Remove belt pulley -arrow-.
- Loosen oil hoses at oil cooler -arrow-.
- Loosen coolant hose clamps and bracket of oil cooler hose -arrows-.
- Remove bolts -arrows- of generator and lay carefully aside on oil pan.
- Disconnect harness connector of DF wire -A- and remove protective cap of B+ wire -B-.
- Remove the B+ wire from generator.
- Loosen wiring clip -arrow-.
- Remove clamp from generator -arrow-.
- Remove generator upward.
Installation
- Installation is the reverse of removal.