Scan Tool Testing and Procedures
Instrument cluster voltage supply for indicators and warning lights, checking with VAG 1598 test boxNotes:
- Use digital multi-meter Fluke 83, VAG 1527 voltage tester; VAG 1598 test box and VAG 1598/8 adapter harness for the following tests.
- Instrument cluster troubleshooting -> Electri Wiring Diagrams, Troubleshooting and Component Locations binder
- Remove instrument cluster
- Disconnect instrument cluster 28-pin harness connector 1-128-
- Connect VAG 1598/8 adapter harness between instrument cluster and wiring harness connector (connectors must engage audibly).
- Connect VAG 1598 Test Box to adapter harness VAG 1598/8.
1 - Instrument cluster
2 - VAG 1598 Test Box
3 - Fluke 83 digital multimeter (different multirr shown)
4 - VAG 1598/8 adapter harness
5 - Instrument cluster 28-pin harness connector T28-
Test requirements
- Battery positive voltage (B+) OK
- Fuse(s) OK (-> wiring diagram)
- Fluke 83digital multimeter set to volt range
Notes:
- If specified values are not obtained, check wiring harness according to wiring diagram.
- If the specified values are obtained in test steps 1 and 2, and instrument cluster still malfunctions, replace instrument cluster