Combination Valve, Checking
Special tools and equipment
- VAG 1390 hand vacuum pump
Test requirements
- No DTCs in DTC memory.
- Output Diagnostic Test Mode (DTM) performed.
- No leaks in vacuum lines or hose connections
- Vacuum hoses not clogged or kinked
Test sequence
- Disconnect vacuum hose -1- at Secondary Air Injection (A1R) solenoid valve (N112) -2-.
- Connect VAG 1390 vacuum pump to vacuum hose -1-.
NOTES: Do not use pressurized air for the following test!
- Disconnect pressure hose -3- at Secondary Air Injection (AIR) pump and blow air in with light pressure (arrow).
Combination valve must close.
- Operate vacuum pump.
Valve must open.
If combination valve does not open:
- Replace the combination valve