Air Door: Service and Repair
Servo Motor For Fresh/Recirculating Air Door - V154-, Removing and Installing
Removing
- Remove glove box.
- Disconnect electrical connector -1-.
- Remove screw -3-.
- Swing motor -2- downwards.
- Disconnect motor -2- from fresh air/recirculating air door lever.
Installing
Replacement motors are supplied with operating levers in the "recirculating air" position. To ease installation, first do the following:
- Attach electrical connector -1- to flap motor -2-
- Switch on ignition.
- Operate button for fresh air/recirculating air and observe lever position.
- When the center position is reached, quickly disconnect the electrical connector.
- Insert motor onto the fresh air/recirculating air shaft -1-.
NOTE: If it is difficult to align and fit the motor to shaft -1-, remove fresh air blower -V2- and position flap/shaft as required. Refer Fig. 4 in "Heating and Ventilation System, Assembly" Service and Repair
- Turn motor in direction of -arrow A-.
- Install mounting screw.
- Reconnect electrical connector.