With Generic Scan Tool
Combination Valve, Checking
Recommended special tools and equipment
- VAG1390 Hand Vacuum Pump
Test requirements
- No leaks in vacuum lines or hose connections.
- Vacuum hoses not clogged or kinked
- Pressure hose for Secondary Air Injection (AIR) Pump Motor not clogged or kinked
Test sequence
NOTE: Do not use pressurized air for the following test.
- Disconnect vacuum hose -1- at Secondary Air Injection (AIR) Solenoid Valve -N112- -2-.
- Disconnect pressure hose -3- at Secondary Air Injection (AIR) pump motor and blow air in with light pressure (arrow).
Combination valve must close.
NOTE: To disengage, compress the buttons at the hose coupling.
- Operate vacuum pump.
Combination valve must open.
If the combination valve does not open or it is constantly open:
- Replace combination valve, item 2.