Windshield Moulding / Trim: Service and Repair
Water Deflector, Assembly Overview
NOTE:
- Description applies to left side. Right side is derived accordingly from this.
- Installation of water deflector minimum 5 hours after installing retaining strip.
- Remove protective foil only immediately prior to installing. Processing temperature approx. 68° F (20° C).
- Bonding surfaces must be dry and free from dust and grease.
1 - water deflector
- Removing:
- Remove water deflector from plenum chamber cover - 4 - starting at retaining strip - 2 -.
- Installing:
- Place water deflector on roof and clip into retaining strip - 2 - from top to bottom.
2 - Retaining strip
- self adhering
- Installing:
- Remove protective foil - 3 -, position retaining strip on inner roof bracing and press on forcefully.
3 - Protective foil
- For adhesive tape of retaining strip.
4 - Plenum chamber cover