Operation CHARM: Car repair manuals for everyone.

Reading




Read Measuring Value Block

Special tools, testers and auxiliary items

- Scan tool VAG 1551 with cable VAG 1551/3

- Connecting scan tool, initiating On Board Diagnostic (OBD).
Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks", under "Restraint Systems", Testing and Inspection
Refer to "Scan Tool Testing, Initiating on Board Diagnostic (OBD)(Central Locking System)". Scan Tool Testing

The measured values in the functions Read Measuring Value Block and basic setting are described during the individual component test. This table serves only as an overview.

The measured value block is divided into 10 display group numbers. The assignment of the individual display zones can be taken from the display group overview. Evaluating Measured Value Blocks

Indicated on display:


Rapid data transfer HELP
Select function XX


- Press keys -0- and -8- (08 initiates the "Read Measuring Value Block" function).

Indicated on display:


Rapid data transfer Q
08 Read Measuring Value Block


- Confirm entry with the Q button.

Indicated on display:


Read Measuring Value Block HELP
Input display group number XX


NOTE: The display group number 001 is an example, to illustrate the sequence.


- Press keys 0, 0 and 1 for "Display group number 1" and confirm entry with Q button.

Indicated on display: (1 to 4 = Display zones)


Read Measuring Value Block 1 ->
1 2 3 4


NOTE: To change to another display group proceed as follows:







- Displayed after pressing C key.

Indicated on display:


Read Measuring Value Block HELP
Input display group number XXX


- Now enter the display group number required.