New Window, Preparing For Installation
New Window, Preparing For Installation
New windows are supplied pre-coated with PUR. The pre-coating consists of items 1, 2 and 3.
1 - Sealing lip
2 - Spacing lip
3 - Area for application of adhesive bead
4 - Window glass
- Rub down pre-coating with a lint-free dry cloth.
WARNING!
Do not prime pre-coat and do not treat with cleaning agent.
- Apply a thin coat of activator D 181 801 A1 only on pre-coat -2- of window using applicator -1- D 009 500 25 (felt ball with wire).
- Allow activator to air dry for at least 10 minutes.
NOTE: Activator must not have contact with paint, otherwise the paint finish will be damaged.