Fuel Filter: Service and Repair
Fuel Tank With Attachments And Fuel Filter, Removing And Installing
1 Cap
2 Seal
- Replace if damaged
3 Mounting bolt
4 Tank lid unit
- with rubber cap
5 Vent line
- Black
- Check for secure fitting
- clipped in at top of fuel tank
6 Ground (GND) connection
- Check for secure fitting
7 Vent line
- white
- Check for secure fitting
8 Gravity valve
- To remove, unclip valve upward from connection
- Checking valve for throughput
Valve vertical: open,Valve tilted 45 degree: closed
9 Seal
- Replace if damaged
10 Change-over valve
- to remove, unclip valve sideways from connection
- before installing, unscrew cap, item 1
11 Vent line
- Black
- Check for secure fitting
12 Pressure retention valve
13 Vent line
- Black
- Check for secure fitting
14 Fuel tank
15 Clamping washer
16 Heat shield
- for fuel tank
17 25 Nm
18 Tightening nut, 2 Nm
19 Cover for fuel tank
20 Tension strap
- Note varying lengths
- Installation position: Locating point (hole) faces direction of travel
21 Supply line
- Black
- Check for secure fitting
- to remove from fuel filter, press release buttons on connecting piece
- to fuel supply line at fuel distributor, Item 8
22 Fuel filter
- Installation position: Arrow points in direction of flow
23 Screw clamp
- Note installed position, Fig. 4.
24 Vent line
- white
- Check for secure fitting
- Clipped in sideways at fuel tank
25 Seal
- Replace if damaged
- to install, place into opening of fuel tank dry
- only coat with fuel when installing Fuel Pump (FP) flange
26 Fuel pump
- Installation position at fuel tank, Fig. 1
- Check fuel pump
- Clean strainer if dirty
27 Union nut, 75 Nm
- Use ring nut spanner 3217 to remove and install
28 Supply line
- Black
- Check for secure fitting
- Clipped in sideways at fuel tank
- to remove from flange and fuel filter, press release buttons on connecting piece
29 Return line
- blue or with blue marking
- Clipped in sideways at fuel tank
- Check for secure fitting
- to remove from flange, press release buttons on connecting piece
30 Connector
- Black, 4-pin
- for Sender for fuel gauge -G- and Fuel Pump (FP) -G6-
31 10 Nm
Fig. 1 Installation position of fuel pump flange
Marking on sensor must align with marking on fuel tank (arrows).
Blue or blue marked return line -1- at connection marked -R-.
Black supply line -2- at connection marked -V-.
NOTE: After installing fuel pump flange, check whether supply, return and vent lines are still clipped in at fuel tank.
Fig. 2 Checking change-over valve
Lever in rest position: closed
Lever pressed in direction of arrow: open
NOTE: Before installing change-over valve, unscrew cover from fuel tank.
Fig. 3 Checking pressure retaining valve
The pressure retention valve is opened from the EVAP canister and Evaporative Emission (EVAP) Canister Purge Regulator Valve -N80- in both flow directions (arrow 1).
It is only opened in one flow direction (arrow 2) on the side of the gravity valve.
Fig. 4 Installation position of fuel filter screw-type clamps
NOTE: Fuel filter is shown in illustration from the front.
- Install screw-type clamps (arrow) as shown in illustration.
Make sure there is enough distance between clamp lock and fuel tank. Dimension "a" must be at least 5 mm.