Fuel Pumps, Checking






Fuel Pumps Checking

Special tools, testers and auxiliary items required

Voltage tester (VAG 1527 B)

Hand multi meter (VAG 1526 C) or Multi meter (VAG 1715)

Connector test set (VAG 1594 C)

Test Conditions

The fuses must be OK

Battery voltage must be at least 11.5 Volts

All electrical consumers such as, e.g. lights and rear window defroster must be switched off

Function and Voltage Supply, Checking

- Fold rear seat bench forward

- Briefly operate the starter. Fuel Pumps (FP) must run audibly.

- Switch off ignition.

If FP Does Not Start Up

Vehicles through Calender Week (CW) 47/06

Vehicles from CW 48/06.

- Cut open carpet from point - A - to point - B - in pre cut area - arrows -.





Right Side of Vehicle

- Remove cover nuts - 1 -. If necessary, backrest support - 2 - or bracket may have to be removed.





Left Side of Vehicle

- Remove bolts - 1 -.

- Then remove nuts - 2 -. Bracket will have to be pressed upward slightly to remove one of the nuts.





Vehicles from CW 48/06

- Remove rear seat bench.

Continuation for All

Check voltage supply of each individual FP as follows:

- Disconnect 4 pin harness connector from right flange of fuel delivery unit.

- Connect diode test lamp (VAG 1527 B) using adapter cables from connector test kit (VAG 1594 C) to outer terminals of connector.





- Switch on ignition, LED must light up for approximately 2 seconds.

If LED does not light up:

- Check activation of fuel pump relay and check wires for open circuit and short circuit.

LED lights up (voltage supply OK):

- Remove right FP unit. Refer to --> [ Fuel Delivery Unit, Fuel Gauge Sensor and Suction Jet Pump ] Fuel Delivery Unit, Fuel Gauge Sensor and Suction Jet Pump.

- Check if the electrical wiring between the flange and fuel pump is connected and has continuity.

If no open circuits are found:

- Right fuel pump is faulty. Replace fuel delivery unit. Refer to --> [ Fuel Delivery Unit, Fuel Gauge Sensor and Suction Jet Pump ] Fuel Delivery Unit, Fuel Gauge Sensor and Suction Jet Pump.

- Repeat test on left fuel delivery unit.

Current pick up of fuel pumps, checking

- Check current draw of each individual FP as follows:

- Connect current clamp of Multi meter (VAG 1715) to the wire of the 4 pin connector contact 1 - arrow - from wiring harness to right fuel delivery unit.





- Start the engine and run at idle speed.

- Measure FP current draw: Specified value: max. 8 amperes.

If the current draw is exceeded:

- Right fuel pump is faulty. Replace fuel delivery unit. Refer to --> [ Fuel Delivery Unit, Fuel Gauge Sensor and Suction Jet Pump ] Fuel Delivery Unit, Fuel Gauge Sensor and Suction Jet Pump.

- Repeat test on left fuel delivery unit.