Valve Body Solenoid Valves, Checking
Diagnostic Procedures
Valve Body Solenoid Valves, Checking
Special tools, testers and auxiliary items required
• Multimeter (VAG1526) or multimeter (VAG1715)
• Connector test kit (VAG1594)
• Wiring diagram
Test requirements
• Respective fuses in fuse box (instrument panel, right) must be OK:
• Selector lever must be in P position.
• Ground (GND) connections to transmission must be OK.
• Ignition switched off.
Test sequence
- Disconnect 14-pin harness connector - arrow 2 - to solenoid valves (Solenoid Valve 1 (N88) to Solenoid Valve 6 (N93), Solenoid Valve 9 (N282), Solenoid Valve 10 (N283)).
Checking resistance
- Check resistances of solenoid valves at connector to the solenoid valves:
• Resistance value is valid at approx. 20° C. At higher temperatures, resistance value increases.
If one of the specified values is not obtained:
- Replace the respective solenoid valve.
- Erase DTC memory of Transmission Control Module (TCM) , Diagnostic mode 4: Reset/erase diagnostic data.
- Generate readiness code.
If specified values are obtained:
- Check wires according to wiring diagram.
Checking wiring
- Connect test box to control module wiring harness , connect test box for wiring test.
- Check wires between test box and 14-pin connector to Transmission Control Module (TCM) for open circuit according to wiring diagram.
- Also check wires for short circuit to each other.
Specified value: infinite ohms
If no malfunctions are found in wires:
- Replace Transmission Control Module (TCM) (J217).