Convenience System Control Module, Coding



Convenience System Control Module, Coding

NOTE:
- When supplied the control module is preceded according to the vehicle equipment.
- The coding is performed with the V.A.G 1551 scan tool. Scan Tool Connecting

- Connecting scan tool. Scan Tool Connecting
- Initiating On Board Diagnostic (OBD). On Board Diagnostic (OBD) For Convenience System, Initiating

Indicated on display:

Rapid data transfer HELP
Select function XX


- Press buttons -0- and -7- (with 07 the function "Code control module" is selected).

Indicated on display:

Rapid data transfer Q
07 Code control module


- Confirm entry with the -Q- button.

Indicated on display:

Code control module Q
Enter code number XXXXX (0-32000)


- Enter code number according to table:

Coding table, vehicles with convenience system > 05.01







Coding table, vehicles with convenience system 06.01 >







- Confirm entry with the -Q- button.

The control module identification number will be displayed with the appropriate index letter, the code number and the workshop code.

1J0959799J 03 Conv. cent. CU 0001 ->
Coding XXXXX WSC XXXXX


If the contents of the display are as shown then the coding is successful.

If the code number entered is not accepted by the control module, the previous coding will appear in the display:

Indicated on display:

1J0959799J 03 Conv. cent. CU 0001 ->
Coding XXXXX WSC XXXXX


In this case the control module has not been programmed with the relevant data for the vehicle. A check must then be completed to see if the correct control module for the vehicle has been installed (compare Part No. and letter index), or whether an incorrect code number has been entered.

- Repeat coding.

If the control module cannot be coded (correct control module, correct code number), the control module is malfunctioning.

Furthermore, at this point the door control module is called-up and checked. End output:

- Press -> button.

Indicated on display:

Rapid data transfer HELP
Select function XX


- Press buttons -0- and -6- to end the output.

Indicated on display:

Rapid data transfer Q
06 End output


- Confirm entry with the -Q- button.

Indicated on display:

Rapid data transfer HELP
Enter address word XX


- Switch off ignition.
- Disconnect connector to V.A.G 1551 scan tool.