Restrictor, Reservoir and A/C Compressor Regulator Valve N280 (Externally Regulated Compressor), Checking
Restrictor, Reservoir And A/C Compressor Regulator Valve N280 (Externally Regulated Compressor), Checking
NOTE:
- Connect service station.
- Observe test conditions
- Set engine speed to 2000 RPM.
- Observe pressure gauge of service station.
NOTE: Switching pressures for actuation of A/C Compressor Regulator Valve N280 and Coolant Fan V7 are vehicle-specific.
Specified values:
High pressure side:
Increasing from initial pressure (on connecting pressure gauges) to 20 bar.
Low pressure side:
Decreasing from initial pressure (on connecting pressure gauges) to value in graph.
A. Low pressure (measured at service connection) in bar absolute.
B. Control current for A/C Compressor Regulator Valve N280.
C. Permissible tolerance range.
NOTE:
- Under unfavorable conditions (very high ambient temperatures, high humidity), pressure on high-pressure side may increase to max. 29 bar.
- Control current - B - is displayed in measured value block.
- High pressure is displayed in measured value block.
- Low pressure settles as a function of control current for A/C Compressor Regulator Valve N280 within compressor output range in tolerance range.
- Under unfavorable conditions (very high ambient temperatures, high humidity), compressor output may not always be sufficient to attain the specified value.
- The specified operating current for the regulating valve must be greater than 0.3 A in order to ensure reliable valve actuation.
- In the setting "maximum cooling output" control current is regulated to approx. 0.8 A (displayed in measured value block).
- At absolute pressure, 0 bar corresponds to absolute vacuum. Normal ambient pressure equals 1 bar absolute pressure. 0 pressure corresponds to an absolute pressure of one bar on most pressure gauges (indicated by -1 bar below 0).