Battery Charger, Connecting
Battery Charger, Connecting
WARNING: Danger of explosion.
- Batteries produce explosive gasses while being charged.
- Keep open flames and sparks away and DO NOT smoke near batteries.
- The battery charger MUST be turned off when connecting or disconnecting the cables at the battery.
- Battery cell caps must NOT be removed while charging.
- "Boosting" a sulfated battery a high charging rate can cause an explosion.
- Ensure that battery is charged in a well ventilated area.
- Precision tools must not be kept in the same room where batteries are being charged. Tools may corrode due to chemical reaction.
CAUTION: In order to prevent damage to the battery or vehicle, observe battery type descriptions and notes.
Special tools and auxiliary items needed
- Battery Charging Station: Midtronics INC-940
NOTE:
- Before charging, battery must have a minimum temperature of 10 degrees C (50 degrees F)
- It is not necessary to remove battery from vehicle or disconnect battery terminals.
- Charging voltage must not exceed 14.4V.
- Always follow the battery charger operating instructions
- After charging, confirm battery no load voltage and electrolyte specific gravity before reuse in vehicle.
CAUTION: Before beginning repairs on the electrical system
- Switch off all electrical consumers.
- Switch ignition off and remove ignition key.
- Connect battery charger to battery, positive to positive (+), negative to negative (-).
- - Switch on battery charger.
- Adjust charging rate according to battery capacity (refer to charger instructions).
WARNING: If battery begins gassing (boiling) violently when charging, REDUCE charging rate immediately.