Climatronic Control Module -J255-, Multi-Pin Connector Assignments
Climatronic Control Module -J255-, Multi-pin Connector Assignments
Special tools, workshop equipment, testers, measuring instruments and auxiliary items required
- VAG 1598/42- test box
- VAG 1598/41 -2- adapter cable
- Template VAG 1598/41-2/4-
Multi-pin connector -A-, in wiring diagram T24ca
1. Center Vent Adjusting Motor -V102- (closed)
2. Defroster Flap Motor Position Sensor -G135-
3. Recirculation Flap Motor Position Sensor -G143-, signal
4. Fresh Air Intake Duct Temperature Sensor -G89-
5. Right Front Upper Body Outlet Temperature Sensor -G386-, signal
6. Right Footwell Vent Temperature Sensor -G262-, signal
7. Left Footwell Vent Temperature Sensor -G261-, signal
8. Actuator for temperature flap left -V158- (open)
9. Center Vent Adjusting Motor -V102- (open)
10. Evaporator Temperature Sensor -G308-
11. Footwell Flap Motor Position Sensor -G468-
12. Potentiometer-actuator for temperature flap right -G221-, signal
13. Potentiometer-actuator for temperature flap left -G220-, signal
14. Center Vent Motor Position Sensor -G467-, signal
15. Left Front Upper Body Outlet Temperature Sensor -G385-, signal
16. Actuator for temperature flap left -V158- (closed)
17. Servo motor for fresh-/recirculating air door -V154- (open)
18. Servo motor for fresh-/recirculating air door -V154- (closed)
19. Actuator for temperature flap right -V159- (open)
20. Actuator for temperature flap right -V159- (closed)
21. Footwell Flap Motor -V261- (open)
22. Footwell Flap Motor -V261- (closed)
23. Side Vent Motor -V262- (open) - Dual-zone Climatronic only
23. Left Side Vent Motor -V299- (open) - Four-zone Climatronic only
24. Side Vent Motor -V262- (closed) - Dual-zone Climatronic only
24. Left Side Vent Motor -V299- (closed) - Four-zone Climatronic only
Multi-pin connector -B-, in wiring diagram T24cb
1. Right Side Vent Motor -V300- - Four-zone Climatronic only
5. Right Front Defrost/Upper Body Shut-off Flap Motor Position Sensor -G317- - Four-zone Climatronic only
9. Right Side Vent Motor -V300- - Four-zone Climatronic only
10. Right Front Upper Body Outlet Position Sensor -G388- - Four-zone Climatronic only
11. A/C Compressor Regulator Valve -N280-
14. Right Footwell Flap Motor Position Sensor -G140- - Four-zone Climatronic only
17. Right Center Vent Motor -V111. - Four-zone Climatronic only
18. Right Center Vent Motor -V111. - Four-zone Climatronic only
19. Actuator for temperature flap right -V159- - Four-zone Climatronic only
20. Actuator for temperature flap right -V159- - Four-zone Climatronic only
Multi-pin connector -C-, in wiring diagram T24cc
5. Side Vent Motor Position Sensor -G469- - Dual-zone Climatronic only
5. Left Front Defrost/Upper Body Shut-off Flap Motor Position Sensor -G318- - Four-zone Climatronic only
6. Defroster Flap Motor -V107- (open)
7. Sunlight Photo Sensor -G107-
8. Front Blower Regulation Sensor (Bitron) -G462- (voltage supply)
12. Front Blower Regulation Sensor (Bitron) -G462- (feedback voltage)
14. Residual Heat Relay -J708-
15. Sunlight Photo Sensor -G107-
17. CAN Bus-High
18. CAN Bus-Low
19. Sensor for air quality -G238-, signal
21. Refrigerant Temperature Sensor -G454-
23. High Pressure Sensor -G65-
24. Defroster Flap Motor -V107- (closed)
Multi-pin connector -D-, vacant
Multi-pin connector -E-, in wiring diagram T12cb
1. +5V for control motors and sunlight penetration sensor
2. Front Blower Regulation Sensor (Bitron) -G462- (activation)
4. A/C Compressor Regulator Valve -N280-
8. Control motor signal Ground (GND) and temperature sensor
9. Terminal 31 - Ground (GND)
10. Terminal 31 - Ground (GND)
11. A/C Compressor Regulator Valve -N280-
12. Signal Ground (GND) for temperature sensor