Operation CHARM: Car repair manuals for everyone.

Fuel Pump, Checking






Diagnostic Procedures


Fuel Pump, Checking

Test requirements

Fuses - 13 - and - 14 - (arrows) in E-box (plenum chamber, left) must be OK:





Fuel Pump (FP) relays I and II must be OK:





1. Fuel Pump (FP) Relay (J17), (Fuel Pump, right)

2. Fuel Pump (FP) 2 Relay (J49), (Fuel Pump, left)

Battery voltage must be at least 11.5 volts.

All electrical consumers such as, for example, lights and rear window defroster must be switched off.

For vehicles with automatic transmission, selector lever must be in P.

Parking brake must be engaged or else daylight driving lights will be switched on.

Ignition switched off.

Observe Safety Precautions.

Observe Clean Working Conditions.

Check function and voltage supply of fuel pumps.

Check delivery quantity, current pick-up, and check valves of Fuel Pumps (FP).

Checking function and voltage supply of fuel pumps

Special tools, testers and auxiliary items required

Multimeter (VAG1526) or multimeter (VAG1715)

Connector test kit (VAG1594)

Wiring diagram

Test sequence, Fuel Pump (FP) (G6), right

Test sequence, Transfer Fuel Pump (FP) (G23), left

- Remove Fuel Pump (FP) Relay (J17), right, from relay carrier, position C20.





Do not use metallic tools to pry off relays from relay carrier. The terminals could conduct electricity.

- Bridge terminals 19d + 19e on relay carrier using appropriate adapter cables.

- Switch ignition on.

Fuel Pump (FP) (G6), right, must start up.

- Switch ignition off.

If Fuel Pump (FP) runs:

- Check activation of Fuel Pump (FP) Relay (J17), right, - 1 - according to wiring diagram:





- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

If Fuel Pump (FP) does not run:

- Remove bridge from terminal 19e.

- Connect multimeter to terminal 19e + Ground (GND) of relay socket for voltage measurement.

- Switch ignition on.

Specified value: at least 11.5 V

- Switch ignition off.

If specified value is not obtained:

- Locate and repair open circuit using wiring diagram:

- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

If specified value is obtained:

- Bridge terminals 19d + 19e on relay carrier using appropriate adapter cables.

- Disconnect 4-pin harness connector (arrow) left, next to fuel tank, at vehicle floor.





- Connect multimeter to terminals 3 + 4 of connector for voltage measurement.





- Switch ignition on.

Specified value: at least 11.5 V

- Switch ignition off.

If specified value is not obtained:

- Locate and repair open circuit using wiring diagram:

- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

If specified value is obtained:

- Fuel Pump (FP) (G6) faulty, replace Fuel Pump (FP) unit , Fuel Pump (FP) unit, fuel gauge sender, and suction jet pump, removing and installing.

- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

Test sequence, Transfer Fuel Pump (FP) (G23), left

- Remove Fuel Pump (FP) 2 Relay (J49), left, from relay carrier, position A6.





Do not use metallic tools to pry off relays from relay carrier. The terminals could conduct electricity.

- Bridge terminals 6d + 6e on relay carrier using appropriate adapter cables.

- Switch ignition on.

Transfer Fuel Pump (FP) (G23), left, must start up.

- Switch ignition off.

If Fuel Pump (FP) runs:

- Check activation of Fuel Pump (FP) 2 Relay (J49), left, - 2 - according to wiring diagram:





- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

If Fuel Pump (FP) does not run:

- Remove bridge from terminal 6e.

- Connect multimeter to terminal 6e + Ground (GND) of relay socket for voltage measurement.

- Switch ignition on.

Specified value: at least 11.5 V

- Switch ignition off.

If specified value is not obtained:

- Locate and repair open circuit using wiring diagram:

- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

If specified value is obtained:

- Bridge terminals 6d + 6e on relay carrier using appropriate adapter cables.

- Disconnect 4-pin harness connector (arrow) left, next to fuel tank, at vehicle floor.





- Connect multimeter to terminals 1 +2 of connector for voltage measurement.





- Switch ignition on.

Specified value: at least 11.5 V

- Switch ignition off.

If specified value is not obtained:

- Locate and repair open circuit using wiring diagram:

- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

If specified value is obtained:

- Transfer Fuel Pump (FP) (G23), left, faulty, replace Fuel Pump (FP) unit , Fuel Pump (FP) unit, fuel gauge sender, and suction jet pumps, removing and installing.

- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

Checking delivery quantity, current pick-up, and check valves of Fuel Pumps (FP)

Test requirement

Function and voltage supply of fuel pumps OK





Special tools, testers and auxiliary items required

Wrench (T10202)

Remote control (VAG1348/3A) with adapter cable (VAG1348/3-3)

Pressure gauge (VAG1318)

Adapter (VAG1318/7)

Adapter (VAG1318/13)

Adapter (VAG1318/17)





Special tools, testers and auxiliary items required

Torque wrench (5 to 50 Nm) (VAG1331)

Torque wrench (40 to 200 Nm) (VAG1332)

Connector test kit (VAG1594A)

Multimeter (VAG1715)

without illustration:

Measuring container

Wiring diagram

Checking fuel delivery

- Remove fuel filler cap from fuel filler tube.

First, reduce fuel pressure as follows:

CAUTION!
The fuel or fuel lines in fuel system can become very hot (danger of scalding)!

In addition, the fuel system is under pressure!Before opening the system, place rags around the connection area and release pressure by carefully loosening the connection!

Wear protective goggles and protective gloves when working on the fuel system!

- Place a rag around separating point to catch escaping fuel.





- Remove fuel supply line (arrow).

When the fuel pressure is reduced:

- Tighten threaded connection again.

Checking fuel delivery:

Fuel Pump (FP) (G6), right ,

Transfer Fuel Pump (FP) (G23), left ,

Fuel Pumps (FP) left and right.

Supply quantity of Fuel Pump (FP) (G6), right, checking

- Connect remote control (VAG1348/3A) to connector (arrow) of Fuel Pump (FP) relay for right Fuel Pump (FP) using adapter (VAG1348/3-3).





- Connect alligator of remote control to B+ connection - 1 -.





- Disconnect fuel supply line - 1 - from fuel distributor.





- Place hose in a measuring container - 2 - of at least 1000 cm3.

- Measuring container must be emptied before measurement.

- Operate remote control

15 seconds:a minimal delivery quantity of

800 cm3/15 seconds must be obtained.

Supply quantity of Transfer Fuel Pump (FP) (G23), left, checking

- Connect remote control (VAG1348/3A) to connector (arrow) of Fuel Pump (FP) relay for left Fuel Pump (FP) using adapter (VAG1348/3-3).





- Connect alligator of remote control to B+ connection - 1 -.





- Disconnect fuel supply line - 1 - from fuel distributor.





- Place hose in a measuring container - 2 - of at least 1000 cm3.

- Measuring container must be emptied before measurement.

- Operate remote control

15 seconds:a minimal delivery quantity of

800 cm3/15 seconds must be obtained.

Supply quantity of both Fuel Pumps (FP), checking

- For this, now connect adapter (VAG1348/3-3) of remote control to connector of Fuel Pump (FP) Relay, left and right:

Connector (arrow) of Fuel Pump (FP) Relay for right Fuel Pump (FP).





Connector (arrow) of Fuel Pump (FP) Relay for left Fuel Pump (FP).





- Connect alligator of remote control to B+ connection - 1 -.





- Disconnect fuel supply line - 1 - from fuel distributor.





- Place hose in a measuring container - 2 - of at least 1000 cm3.

- Measuring container must be emptied before measurement.

- Operate remote control

10 seconds:a minimal delivery quantity of

800 cm3/10 seconds must be obtained.

If the minimal delivery quantity is not obtained during one of the tests:

- Check fuel lines for possible restrictions (kinks) or clogging.

If the lines are OK:

- Replace filter element in fuel filter.

- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

Delivery rate has been obtained, but malfunctions are still suspected in the fuel supply (e.g. sporadic loss of fuel supply):

- Check current pick-up of Fuel Pumps (FP)

Checking current pick-up of Fuel Pumps (FP)

Check current pick-up of each individual Fuel Pump (FP) as follows:

- Re-connect all disconnected fuel lines.

- Cut through floor carpet from point - A - to point - B - in pre-cut area (arrows).





- Unscrew nuts - 1 - of cover. Remove backrest support - 2 - or mounting bracket if necessary.





- Connect multimeter with electrical current probe to wire of 4-pin connector terminal - 1 - (arrow) from wiring harness to Fuel Pump (FP), right.





- Start engine and let run at idle.

- Measure Fuel Pump (FP) current draw.

Specified value: max. 11 amperes

If current draw is exceeded:

- Fuel Pump (FP), right, faulty, replace Fuel Pump (FP) unit , Fuel Pump (FP) unit, fuel gauge sender, and suction jet pumps, removing and installing.

- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

- Repeat test on Fuel Pump (FP), left.

If current draw is exceeded:

- Fuel Pump (FP), left, faulty, replace Fuel Pump (FP) unit , Fuel Pump (FP) unit, fuel gauge sender, and suction jet pumps, removing and installing.

- Erase DTC memory of Engine Control Module (ECM) , Diagnostic mode 4: Reset/erase diagnostic data.

- Generate readiness code.

If malfunction in fuel system is sporadic, test can also be performed during a road test, but a second person is required.